Gas Safe registered installation North Wales & the North WestMy account
Ideal Heating · OWNER INFORMATION

Logic
manuals & guides.

Official guides, everyday controls, manufacturer cover and model-specific fault information for the Ideal Heating Logic.

Find official documents
Ideal Heating Logic

Make sure it’s your model.

Logic, Logic Combi2, Logic+, MAX and ESP1 names identify different versions. The Combi2 PDF below applies only when that generation matches your appliance.

FROM THE MANUFACTURER

Official documents & links.

EVERYDAY USE

How to use your boiler.

Your boiler supplies heating and hot water on demand. Its heating-water setting, tap-water setting and room thermostat do different jobs. Use the fitted room controller for times and desired room temperature, and the matching boiler guide for normal water-temperature menus.

  1. Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
  2. Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
  3. Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
  4. Use the right hot-water controls. Use the tap-water setting described in the combi guide; it is separate from room temperature.
  5. Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
  • The room thermostat controls the room temperature and the programmer controls heating times. Boiler water settings are separate.
  • Logic and Logic2 displays differ. Codes such as F1 and F01 must be matched to the actual generation.
  • For system and heat-only installations, use the cylinder and programmer instructions as well as the boiler guide.

Your manufacturer cover.

2-year standard manufacturer cover. Annual servicing and manufacturer terms apply.

Ideal Heating cover, registration & servicing

If something isn’t working.

Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

9 matching code or status examples

DisplayWhat it meansYour next step
F1Fault / maintenance message

System water pressure is too low.

Older Logic combi; match generation before using F1-style codesManufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
F2Fault / maintenance message

The flame has been lost.

Older Logic combi; match generation before using F1-style codesManufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F3Fault / maintenance message

A fan fault is reported.

Older Logic combi; match generation before using F1-style codesManufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F4 / L4Fault / maintenance message

A heating-flow sensor fault is reported.

Older Logic combi; match generation before using F1-style codesManufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F01Fault / maintenance message

System pressure is too low.

Logic Combi2 C24/C30/C35; UIN237664 A01, October 2023Official Logic2 user guide ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
F02Fault / maintenance message

The flame has been lost.

Logic Combi2 C24/C30/C35; UIN237664 A01, October 2023Official Logic2 user guide ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F03Fault / maintenance message

A fan fault is reported.

Logic Combi2 C24/C30/C35; UIN237664 A01, October 2023Official Logic2 user guide ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
L01Fault / maintenance message

Overheating or no water flow has been detected.

Logic Combi2 C24/C30/C35; UIN237664 A01, October 2023Official Logic2 user guide ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
L02Fault / maintenance message

The boiler has locked out during ignition.

Logic Combi2 C24/C30/C35; UIN237664 A01, October 2023Official Logic2 user guide ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.

More help for your home.

Back to all boiler manuals