Make sure it’s your model.
Match Logic System versus System2, Logic+ and MAX. The System2 PDF below is specific to that generation.
Official documents & links.
Ideal Heating user guides
Choose user or operating instructions. Match the full appliance identification, boiler type, output and generation. Boiler and thermostat guides can be separate.
Opens the manufacturer’s website in a new tabLogic System2 official user guide
Only for Logic System2, UIN237665 A01, October 2023. Match the generation; older Logic System and MAX guides differ.
Opens the manufacturer’s website in a new tabHow to use your boiler.
The boiler works with a separate hot-water cylinder. Heating times and room temperature come from the fitted controller; stored hot-water operation also depends on the programmer and cylinder controls. Keep cylinder settings as commissioned and ask the installer before changing them.
- Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
- Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
- Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
- Use the right hot-water controls. Use the fitted programmer and cylinder controls. Keep stored-water settings as commissioned and ask your installer about changes.
- Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
- The room thermostat controls the room temperature and the programmer controls heating times. Boiler water settings are separate.
- Logic and Logic2 displays differ. Codes such as F1 and F01 must be matched to the actual generation.
- For system and heat-only installations, use the cylinder and programmer instructions as well as the boiler guide.
Your manufacturer cover.
2-year standard manufacturer cover. Extended cover is only included if confirmed in your written quote. Annual servicing and manufacturer terms apply.
Ideal Heating cover, registration & servicingIf something isn’t working.
Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.
These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.
5 matching code or status examples
| Display | What it means | Your next step |
|---|---|---|
| F01Fault / maintenance message | System pressure is too low. Logic System2; UIN237665 A01, October 2023Official Logic2 user guide ↗ | Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer. |
| F02Fault / maintenance message | The flame has been lost. Logic System2; UIN237665 A01, October 2023Official Logic2 user guide ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| F03Fault / maintenance message | A fan fault is reported. Logic System2; UIN237665 A01, October 2023Official Logic2 user guide ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| L01Fault / maintenance message | Overheating or no water flow has been detected. Logic System2; UIN237665 A01, October 2023Official Logic2 user guide ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| L02Fault / maintenance message | The boiler has locked out during ignition. Logic System2; UIN237665 A01, October 2023Official Logic2 user guide ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
Open Ideal Heating’s official fault reference ↗ · Find the matching user manual
Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.