Gas Safe registered installation North Wales & the North WestMy account
Viessmann · OWNER INFORMATION

Vitodens 050-W
manuals & guides.

Official guides, everyday controls, manufacturer cover and model-specific fault information for the Viessmann Vitodens 050-W.

Find official documents
Viessmann Vitodens 050-W

Make sure it’s your model.

Match the appliance type and serial number, including B0KA/B0HA where stated. Different 050-W generations use different displays and fault codes.

FROM THE MANUFACTURER

Official documents & links.

EVERYDAY USE

How to use your boiler.

Your boiler supplies heating and hot water on demand. Its heating-water setting, tap-water setting and room thermostat do different jobs. Use the fitted room controller for times and desired room temperature, and the matching boiler guide for normal water-temperature menus.

  1. Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
  2. Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
  3. Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
  4. Use the right hot-water controls. Use the tap-water setting described in the combi guide; it is separate from room temperature.
  5. Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
  • Search ViBooks using the article or serial number, then choose operating instructions for the boiler and the fitted control unit.
  • Use normal heating, hot-water and scheduling menus described by the operating guide. A commissioning Quickstart is an installer document.
  • Fault-code meanings depend on appliance type and generation. The current 050-W numerical table is not a universal Vitodens table.

Your manufacturer cover.

7-year manufacturer warranty subject to eligible registration within 30 days and annual servicing. Longer cover is only included if expressly confirmed in your written quote; paid service plans are separate.

Viessmann cover, registration & servicing

If something isn’t working.

Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

5 matching code or status examples

DisplayWhat it meansYour next step
62Fault / maintenance message

The high-limit safety cut-out has operated.

Vitodens 050-W B0HA/B0KA only; manual 6194588 GB, December 2022Manufacturer code definitions; engineer manual 6194588 ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
64Fault / maintenance message

The flame was lost during stabilisation or operation.

Vitodens 050-W B0HA/B0KA only; manual 6194588 GB, December 2022Manufacturer code definitions; engineer manual 6194588 ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
71Fault / maintenance message

Fan speed is too low.

Vitodens 050-W B0HA/B0KA only; manual 6194588 GB, December 2022Manufacturer code definitions; engineer manual 6194588 ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
74Fault / maintenance message

System pressure is too low.

Vitodens 050-W B0HA/B0KA only; manual 6194588 GB, December 2022Manufacturer code definitions; engineer manual 6194588 ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
75Fault / maintenance message

Water flow has not been detected.

Vitodens 050-W B0HA/B0KA only; manual 6194588 GB, December 2022Manufacturer code definitions; engineer manual 6194588 ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.

More help for your home.

Back to all boiler manuals