Make sure it’s your model.
Greenstar 8000 Life is a separate, older range from 8000+ and Style. Match the boiler type and manufacture period rather than choosing by the number 8000 alone.
Official documents & links.
How to use your boiler.
Your boiler supplies heating and hot water on demand. Its heating-water setting, tap-water setting and room thermostat do different jobs. Use the fitted room controller for times and desired room temperature, and the matching boiler guide for normal water-temperature menus.
- Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
- Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
- Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
- Use the right hot-water controls. Use the tap-water setting described in the combi guide; it is separate from room temperature.
- Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
- Greenstar display layouts differ between the 1000, 2000, 4000, 8000 Life, 8000+ and older ranges. Use the matching user instructions.
- Set room temperature and heating times on the fitted room control. Combi hot water and cylinder-controlled hot water use different arrangements.
- Some displays show operating or maintenance messages as well as faults. Record every letter, number and accompanying description.
Your manufacturer cover.
Manufacturer cover and eligibility for remaining stock are confirmed in your written quote before ordering. Annual servicing and manufacturer terms apply.
Worcester Bosch cover, registration & servicingIf something isn’t working.
Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.
These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.
3 matching code or status examples
| Display | What it means | Your next step |
|---|---|---|
| 1017Fault / maintenance message | Heating water pressure is too low. Greenstar 8000 Life combi; manual 6720883858Manufacturer fault reference ↗ | Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer. |
| 227Fault / maintenance message | The boiler has not detected a flame after ignition. Greenstar 8000 Life combi; manual 6720883858Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| 224Fault / maintenance message | The safety temperature limiter has operated. Greenstar 8000 Life combi; manual 6720883858Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
Open Worcester Bosch’s official fault reference ↗ · Find the matching user manual
Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.