Official guides, everyday controls, manufacturer cover and model-specific fault information for the Baxi Assure 500 Combi 2.

Find official documents
Baxi Assure 500 Combi 2

Make sure it’s your model.

Match Assure 500 Combi 2, including the “2”. The Assure 524 Combi 2 is the 24 kW starting model. Older Baxi 500 documents and code tables are different.

FROM THE MANUFACTURER

Official documents & links.

EVERYDAY USE

How to use your boiler.

Your boiler supplies heating and hot water on demand. Its heating-water setting, tap-water setting and room thermostat do different jobs. Use the fitted room controller for times and desired room temperature, and the matching boiler guide for normal water-temperature menus.

  1. Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
  2. Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
  3. Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
  4. Use the right hot-water controls. Use the tap-water setting described in the combi guide; it is separate from room temperature.
  5. Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
  • Assure 500 Combi 2 has heating and hot-water settings; the fitted room control sets room temperature and heating times.
  • Assure 500 System 2 and Assure Heat use an existing hot-water cylinder and external controls. Keep the cylinder settings as commissioned and ask the installer about changes.
  • Combi & System 2 use a different fault-code format from older Baxi families. Match the full model before using a code table.

Your manufacturer cover.

2-year manufacturer parts and labour warranty, subject to correct installation, registration and annual servicing. Any longer cover must be confirmed in your written quote; servicing is separate.

Baxi cover, registration & servicing

If something isn’t working.

Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

6 matching code or status examples

DisplayWhat it meansYour next step
A.02.06Fault / maintenance message

Heating-system pressure warning.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
H.02.07Fault / maintenance message

Low heating-circuit pressure continues.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
E.04.10Fault / maintenance message

Ignition has failed after four attempts.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
E.04.13Fault / maintenance message

Fan impeller obstruction or excessive fan speed.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
E.01.17Fault / maintenance message

Circulation has stopped; a permanent fault is recorded.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
H.03.02Fault / maintenance message

Temporary loss of flame.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.