Record the full message.
Include the exact model, complete code, displayed text and whether heating, hot water or both are affected. A photograph of the display can help.
Find plain-language meanings for selected Baxi fault and status messages, with the exact model or generation shown. Use your matching operating instructions before taking any owner action.
These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.
6 matching code or status examples
| Display | What it means | Your next step |
|---|---|---|
| A.02.06Fault / maintenance message | Heating-system pressure warning. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer. |
| H.02.07Fault / maintenance message | Low heating-circuit pressure continues. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer. |
| E.04.10Fault / maintenance message | Ignition has failed after four attempts. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| E.04.13Fault / maintenance message | Fan impeller obstruction or excessive fan speed. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| E.01.17Fault / maintenance message | Circulation has stopped; a permanent fault is recorded. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
| H.03.02Fault / maintenance message | Temporary loss of flame. Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗ | Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer. |
Open Baxi’s official fault reference ↗ · Find the matching user manual
Include the exact model, complete code, displayed text and whether heating, hot water or both are affected. A photograph of the display can help.
Follow only the normal owner instructions for your model. Do not remove the casing, open service menus or attempt gas, fan, sensor or internal electrical work. Avoid repeated resets.
A code describes a condition, not a confirmed failed part. Persistent faults need the manufacturer or a Gas Safe engineer. Tell your landlord or agent if you rent.
Ask our teamManufacturer references checked 29 November 2026. The examples are not a complete diagnostic table or a repair instruction.