Baxi · OWNER INFORMATION

Assure 500 System 2
manuals & guides.

Official guides, everyday controls, manufacturer cover and model-specific fault information for the Baxi Assure 500 System 2.

Find official documents
Baxi Assure 500 System 2

Make sure it’s your model.

Match Assure 500 System 2. The Assure 515 System 2 is the 15 kW starting model; a combi manual does not describe the cylinder controls.

FROM THE MANUFACTURER

Official documents & links.

EVERYDAY USE

How to use your boiler.

The boiler works with a separate hot-water cylinder. Heating times and room temperature come from the fitted controller; stored hot-water operation also depends on the programmer and cylinder controls. Keep cylinder settings as commissioned and ask the installer before changing them.

  1. Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
  2. Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
  3. Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
  4. Use the right hot-water controls. Use the fitted programmer and cylinder controls. Keep stored-water settings as commissioned and ask your installer about changes.
  5. Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
  • Assure 500 Combi 2 has heating and hot-water settings; the fitted room control sets room temperature and heating times.
  • Assure 500 System 2 and Assure Heat use an existing hot-water cylinder and external controls. Keep the cylinder settings as commissioned and ask the installer about changes.
  • Combi & System 2 use a different fault-code format from older Baxi families. Match the full model before using a code table.

Your manufacturer cover.

Manufacturer cover is confirmed for the exact model and registration route in your written quote. Annual servicing and manufacturer terms apply; servicing is separate.

Baxi cover, registration & servicing

If something isn’t working.

Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

6 matching code or status examples

DisplayWhat it meansYour next step
A.02.06Fault / maintenance message

Heating-system pressure warning.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
H.02.07Fault / maintenance message

Low heating-circuit pressure continues.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
E.04.10Fault / maintenance message

Ignition has failed after four attempts.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
E.04.13Fault / maintenance message

Fan impeller obstruction or excessive fan speed.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
E.01.17Fault / maintenance message

Circulation has stopped; a permanent fault is recorded.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
H.03.02Fault / maintenance message

Temporary loss of flame.

Baxi Assure 500 Combi 2 / System 2Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.