Vaillant · OWNER INFORMATION

ecoFIT pure
manuals & guides.

Official guides, everyday controls, manufacturer cover and model-specific fault information for the Vaillant ecoFIT pure.

Find official documents
Vaillant ecoFIT pure

Make sure it’s your model.

Match Vaillant ecoFIT pure, the combi boiler type, exact output, manufacture period and model or serial reference. Our listed outputs are 25, 30, 35 kW. Read an accessible external label or installation paperwork; do not remove the casing.

FROM THE MANUFACTURER

Official documents & links.

EVERYDAY USE

How to use your boiler.

Your boiler supplies heating and hot water on demand. Its heating-water setting, tap-water setting and room thermostat do different jobs. Use the fitted room controller for times and desired room temperature, and the matching boiler guide for normal water-temperature menus.

  1. Identify the controls. Match the boiler model and the fitted room thermostat to their user guides.
  2. Check the normal display. Use the operating guide to recognise heating, hot-water, standby and status symbols. Keep installer and service menus for your engineer.
  3. Set your heating routine. Check the room control’s clock, heating programme and desired room temperature. Change one normal setting at a time.
  4. Use the right hot-water controls. Use the tap-water setting described in the combi guide; it is separate from room temperature.
  5. Keep the instructions handy. Ask for a demonstration if a setting, pressure display or mode is unfamiliar. Follow the manufacturer’s frost-protection guidance before switching off power.
  • Use the operating instructions for the exact ecoFIT or ecoTEC model and boiler type. A combi guide is not an open-vent Heat guide.
  • The fitted thermostat or controller determines the heating demand and schedule. On cylinder systems, stored hot water has separate controls.
  • Current ecoTEC plus may display F.022 or F.028, while other versions show F.22 or F.28. Keep all digits when reporting a fault.

Your manufacturer cover.

2-year standard manufacturer cover. Ten years requires qualifying Vaillant Advance/myREWARDS registration and Boiler Protection Kit; subject to eligible installer registration. Annual servicing and manufacturer terms apply.

Vaillant cover, registration & servicing

If something isn’t working.

Note the exact display message, whether heating or hot water is affected and when it happens. Follow only the user actions in your matching manual. If the issue persists or the instructions are unclear, contact a qualified engineer. Do not remove the casing or attempt gas or internal electrical work.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

2 matching code or status examples

DisplayWhat it meansYour next step
F.22Fault / maintenance message

The sealed heating circuit has insufficient water pressure.

ecoFIT pure combi 825–835; operating manual 0020230532Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
F.28Fault / maintenance message

The boiler has not established ignition.

ecoFIT pure combi 825–835; operating manual 0020230532Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Official sources checked 29 November 2026. Examples are model-specific; the matching manufacturer instructions contain the complete code table.