VAILLANT · DISPLAY MESSAGES

A code on the screen?
Start with the model.

Find plain-language meanings for selected Vaillant fault and status messages, with the exact model or generation shown. Use your matching operating instructions before taking any owner action.

Vaillant fault-code meanings.

These are selected manufacturer-verified examples. Match the model and generation shown in each row; the official instructions contain the full table. A normal status message is labelled separately.

8 matching code or status examples

DisplayWhat it meansYour next step
F.22Fault / maintenance message

The sealed heating circuit has insufficient water pressure.

ecoFIT pure combi 825–835; operating manual 0020230532Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
F.28Fault / maintenance message

The boiler has not established ignition.

ecoFIT pure combi 825–835; operating manual 0020230532Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F.022Fault / maintenance message

Insufficient water quantity or pressure is reported.

Current ecoTEC plus 610–635 system / 826–840 combi; operating manual 0020308119Manufacturer fault reference ↗
Check the visible pressure display against the matching user guide. Only follow a filling procedure you have been shown and understand. Recurring pressure loss needs an engineer.
F.028Fault / maintenance message

A flame has not been detected during ignition.

Current ecoTEC plus 610–635 system / 826–840 combi; operating manual 0020308119Manufacturer fault reference ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
S.000Operating status

There is no heating demand.

Current ecoTEC plus; operating manual 0020308119ecoTEC plus operating instructions ↗
This is an operating status, not a fault by itself. Check the heating programme and desired room temperature if you expected a different mode.
S.004Operating status

The heating burner is operating.

Current ecoTEC plus; operating manual 0020308119ecoTEC plus operating instructions ↗
This is an operating status, not a fault by itself. Check the heating programme and desired room temperature if you expected a different mode.
F.28Fault / maintenance message

Ignition has not been established.

ecoFIT pure open vent 412–435Official operating instructions ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.
F.28Fault / maintenance message

Ignition has not been established.

ecoTEC plus open vent 412–435Official operating instructions ↗
Record the full message and contact a Gas Safe engineer or the manufacturer if it persists. Internal diagnosis and repair need an engineer.

Record the full message.

Include the exact model, complete code, displayed text and whether heating, hot water or both are affected. A photograph of the display can help.

Keep checks at user level.

Follow only the normal owner instructions for your model. Do not remove the casing, open service menus or attempt gas, fan, sensor or internal electrical work. Avoid repeated resets.

Get the right help.

A code describes a condition, not a confirmed failed part. Persistent faults need the manufacturer or a Gas Safe engineer. Tell your landlord or agent if you rent.

Ask our team

Choose your exact boiler guide.

Manufacturer references checked 29 November 2026. The examples are not a complete diagnostic table or a repair instruction.